Series 1500 Liquid Turbine Meters

Custody transfer reliability

Ideal for a variety of crude oil and refined product applications, Daniel® Series 1500 Liquid Turbine Meters are the volumetric flow measurement instruments of choice for petroleum manufacturers and distributors worldwide. A unique stainless steel internal assembly maximizes volume throughput and minimizes pressure drop, enabling high flow rates over an extended flow range. Rugged, next-generation electronics integrate two pickoff coils and a highly durable dual-channel preamplifier to guarantee total pulse integrity, virtually eliminating the possibility of missing or double-counted pulses. Improve functionality by pairing the meter with the backlit Daniel DRT-899 Rate/Totalizer to streamline access to critical flow data.

Coming Soon:

Line Size DN25 to DN600 (1-in to 24-in)
Fluid Type Liquid
Linearity (standard) 1-in to 2.5-in: ±0.25%; 3-in to 24-in: ±0.15%

*Note: Please note that repeatability of Turbine Meters can only be demonstrated under specific calibration conditions which involve the uncertainty of the laboratory. For specific details, please contact your Emerson local representative.

Repeatability ±0.02%
Process Temperature Range (standard) • Carbon Steel: -29°C to +60°C (-20°F to +140°F)
• Stainless Steel: -40°C to +60°C (-40°F to +140°F)
Operating Pressure Range Carbon steel and stainless steel
Electronics 2 pickoff coils and Dual-Channel Preamplifier (standard); additional Preamplifier models available to meet application requirements
  • Achieve higher flow rates and an extended flow range with unique stainless steel internal assembly
  • Improve fiscal measurement accuracy with a pulse output linear with flow rate and 10:1 rangeability (turndown)
  • Maximize accountability with high-frequency pulse resolution that enables measurement of minute increments
  • Improve electronics performance with superior combination of dual-channel preamplifier and two pickoff coils
  • Eliminate missing or double-counted pulses by achieving total pulse integrity with standard second pickoff coil
  • Streamline local access to critical flow data with the Daniel DRT-899 Rate/Totalizer that features a backlit display
  • Simplify maintenance with new threaded lid that allows easy access to preamplifier and pickoff coil(s)
  • Easily upgrade UMB-equipped meters to the new LME housing that features potted electronics to improve durability
Line Size DN50 to DN200 (2-in to 8-in)
Fluid Type Liquid
Operating Temperature Range -29º C to +66º C (-20º F to +150º F)
Operating Pressure Range ANSI 150 to 300
Materials: Valve Body Carbon Steel, ASTM A352 GR LCC
Materials: Valve Cylinder DN50 to DN 200 (2-in to 4-in): Stainless Steel, ANSI 150 to 600; DN250 to DN 300 (6-in to 8-in) Carbon Steel, Nickel Coated, ANSI 150 to 600
Materials: Valve Piston Standard: Stainless Steel
Materials: Seat Ring DN50 to DN200 (2-in to 6-in) Stainless Steel; DN300 (8-in) Carbon Steel, Nickel Coated
Materials: O-Rings Standard: Viton; Optional: Neoprene, EPR, Kalrez / Teflon AP (Aggressive Products)