Daniel® Coriolis Mass Flow Meters
Coriolis Meter Theory
he TDaniel® Coriolis Mass Flow Meters operate on the principle of the Coriolis effect, where fluid flow through vibrating tubes induces measurable changes proportional to the mass flow rate. As fluid enters the meter, it is directed through oscillating sensor tubes. The mass flow of the fluid causes a phase shift in these oscillations, directly correlating to the mass flow rate. This direct measurement technique ensures high accuracy and reliability, making Coriolis meters ideal for various applications, including custody transfer and process control.